珠海市希望电子有限公司
User Manual
High Voltage BMS 16S-512S with active balance 2A communicate with Inverters GOODWE/GROWATT/SOFAR/MEGAREVO/INVT/DEYE/KOYOE/PYLON/SOLAX/SOLIS/Fox-ESS/LUXPOWER via canbus
Sep,17,2026


   HIGH VOLTAGE BMS 16S-512S WITH ACTIVE BALANCE 2A


   

HV BMS/High Voltage BMS 16S ~512S with active balance 2A for photovatic energy storage; 

The high voltage bms can communicate with these HV Inverters:DEYE,GOODWE,ATESS,SOFAR,INVT_BD,PYLON,GROWATT,MEGAREVO,KOYOE,AFOFE,

Solax(X1/X3-Hybrid-G4),Solis,Sunways,SINEXCEL-PCS,AISWEI ,Bluesun,

FOX-ESS,LUXPOWER, Sungrow; 

This HV BMS/High Voltage BMS 16S ~512S can keep balancing cells at 2 ampere 

and you can set cell balancing starting voltage (range 1.5V-4.2V) and cell voltage difference >= 10MV; 

This High Voltage BMS is compatible with Both Lithium-ion batteryand Lifepo4 Battery / lithium-titanate battery/Sodium ion battery ;


主动均衡接线图.jpg









Test Video of  Balancing Performance :


This High Voltage BMS is compatible with Lithium-ion battery /Lifepo4 Battery / lithium-titanate battery/Sodium ion battery 

This HV BMS/High Voltage BMS 16S ~512S can keep balancing cells at 2 ampere and you can set  cell balancing starting voltage (range 1.5V-4.2V) and cell voltage difference >= 10MV; 


image.png


and you can switch on or switch off active balance in the  bms pc software , Please see below :

image.png






New Version of HV BMS wiring scheme :



New wiring scheme.jpg


For better resolution of bms diagram ,please check the inserted PDF file;

New Version of BMS wiring scheme_V1.6.pdf


Attention : when you do wiring , please check whether or not  the ground of the DC-DC  power supply is connected to the

housing of the high Voltage  box, and the housing of the high voltage  box should be grounded. And the case of all batteries

should also be grounded!


This bms can talk to inverter:


(DEYE,GOODWE,ATESS,SOFAR,INVT_BD,PYLON,GROWATT,MEGAREVO,KOYOE,AFOFE,Solax,Solis,

Sunways,SINEXCEL-PCS,AISWEI ,Bluesun,FOX ESS,Luxpower)


图像 36.jpg



  • Master BMS Configuration PC Softwarfe(Password: 123456)

TOPBms_Toolkits_2026_0120.rar


The lastest Version of BMS Newest Firmware 

HW17X_V53A_2026_0416-Final.rar


The firmware can solve F56 /F57 /F58 Error which appears in the deye inverter !!



c7e15824658e286e9cd6bbbfebfaf111.jpg



Please update your master bms with the firmware V533;

Before firmware update , please save all configuration,after firmware update , please selcect  " deye 德业“ in BMS pc software;


image.png



But you need to be aware of the following points which can cause the F56 /F57 Error as well:

  • DC wire unable to handle amper of discharging add a 25mm wire from your battery to inverter;

  • if your battery gets equal or lower to shutdown value, it will throw an error.. you need to manualy restart your inverter

  • Your battery maybe 30% or 70% or 90%, but if it is lower than Shutdown, F56 will happen.

    image.png



How to change language of pc software ? 

How to enter passowrd before you configurate bms ? See below 

BMS Monitoring-4.jpg



Master BMS is used to configurate the charging cut-off / discharging cut-off /Over current cut-off / Balance starting /Inverter Communication / Inverter charging cut-off / Invert discharging cut-off /Cell strings ,etc. Let me take BMS 48S for example ,

please see the following configuration


图像 3.jpg




图像 13.jpg



What is the standby current ? 

 Standby current means BMS self power consumption which  is 500mA ; Please enter 500 here ;Please see below :


image.png



Before you set /calculate SOC , please enter password: 123456;

How to get correct SOC now?

Set the design capacity / full capacitu / residual capacity in the pc software as below ;

regarding the residual capacity , please enter 1/2 full capacity

and then take a complet cycle of discharging and charging ; finally the SOC will be calibrated automatically 


图像 100.jpg



How to calibrate the current ?

Please adjust the FL CHG/FLDSG factors  if charge current discharge current is not in line with actual current  



图像 10.jpg




1696900503753419.jpg



Before current calibration , please check if the setting of shunt is in line with the actual parameters of the shunt you use


图像 14.jpg



How to set " Standy by curremt ",“Zero diff Current ” , "Zero Current"


Zero Current .jpg



How to set cell balancing in the PC software ?



图像 101.jpg



HV BMS Montoring User  Manual 

HV BMS Monitoring System.pdf

How to get display work ?


图像 6.jpg



if you don't select "DWIN TFT" , the display show all " 0"



图像 7.jpg



Display Instruction of HV BMS- TOPBMS

Display Instruction of HV BMS- TOPBMS.pdf








Cable for  RS485 to USB


Driver Software (UT-8890)of  Converter of RS485 to USB



2023-01-08 11 12 03.jpg



UT-8890 驱动.rar


Driver Software (UT-885/890/2003A/880/8801)of  Converter of RS485 to USB




T-885、890、2003A、880、8801  DRIVER.rar


Driver Software (CH340 for Win11)

CH340 driver for  Win 11.zip

Driver Software (CH340 for Win7,8,9,10)

CH348 Driver for win7 ,8 ,10.zip


You need to change the settings of converter via RS485 transmission cable ; if not , the converter cannot work properly 



2023-02-08 15 34 27.jpg



Master BMS Firmware Update :


、

图像 7.jpg



Battery capacity Settings in the BMS Monitoring Systerm Software 



图像 100.jpg