Detail

TOPBMS High Voltage BMS 12S-240S with active balancing 2A 

微信图片_20241014155911_美图抠图20241014.jpg




PC Software ; Please install bms pc software and drive software  in the pc before you configurate bms


TOPBMS上位机-  English.rar

Driver software .zip

How to use BMS PC Software ? Please see the below instruction 

  • How to connect bms to pc ?

First of all , please adjust the PC Display screen scaling and layout to 100%  like below :

图像 34.jpg


and then You need to connect master bms to PC via the adaptor of canbus to USB via CAN 1 


image.png

image.png

  • The computer needs to select the correct time format(YEAR-MONTH-DAY) as following before you use BMS pc software;

 otherwise , The BMS pc sofware can not work well;

Correct Format

图像 20.jpg

Wong Format

图像 21.jpg

and afterwards , you can open the bms pc software as below :

Open Device--->Z CAN USB CAN1---> 500K (Baud Rate)

图像 113.jpg

图像 112.jpg

  • You can set Port  CAN 1 or  Port CAN2  for communication port between master bms and PC or between Master BMS and Inverter /PCS

The following Main parameters settings are configurated before BMS leave factory;Please don't change them ;


标准主页面.jpg

The other Parametes settings (Cell voltage ,charge current ,discharge current,SOC, temperature)

  • 3-level parameters setting ;  

 If  BMS level 1 and level 2 alarms, the relay will disconnect and then automatically re-close; If  level 3 alarms, manual restart of BMS is required.

图像 92.jpg


  • How to set the battery strings and NTC? Please see " Batter _Configuration"

图像 91.jpg

  • Real Time Monitoring Of Voltage and Temperature

图像 95.jpg

  • The charging and discharging quantities should be reset to zero. This needs to be done by filling in "zero" at the initial value section on the home page.

图像 24.jpg

Before you change parameters , you need to enter "23710“  in the key and and  click  this bottom button"parameter download" and then the dialog window pops up as below , you need to click " cancel" ,and then you start parameter settings/change ,and then  click button"parameter download" again and the parameter setting/change is finished successfully ;

图像 19.jpg

Anyway , it is recommended that we can help you to do bms configuration via anydesk ; 

Please let us know if you need parameters settings/change ;

our whatsapp: +8617841591535; email: zhxiwangdianzi@126.com


Wiring Diagram for Solar Energy Storage 

Wiring scheme for BCU-B3 - ENG-Solar energy storage.pdf

Wiring scheme for slave bms 24S- ENG.pdf

Wiring scheme for slave bms 12S- ENG - without fan.pdf

Wiring scheme for slave bms 36S- ENG.pdf

Wiring Diagram for EV

Wiring Scheme for BCU-Q3-ENG-EV.pdf

Wiring scheme for slave bms 24S- ENG.pdf